2-3
Section
Power Supply and Ground
10
2-3
Power Supply and Ground
Wire the power supply and the ground to the top terminal block,
and tighten the screws to a torque of between 0.5 and 0.6 N
S
m.
After wiring, check to make sure that the wiring is correct.
WARNING
Cover the terminal blocks with the Terminal Block Protection
Covers. Uncovered terminal blocks can result in electric shock.
2-3-1
Crimp Terminals and Cables
The terminal block uses M3 terminal screws. Use appropriate
crimp terminals for M3 screws, as shown below.
Forked
Round
6.2 mm max.
6.2 mm max.
Applicable wire size: Insulated wire, 1.31 to 1.65 mm
2
(AWG16
to AWG15)
2-3-2
Protective Conductor (Earth) Wiring
Ground of 100
Ω
or
less.
Note
1. Use an appropriate ground. An insufficient ground can af-
fect V530-R150 operation or result in damage to
V530-R150 components.
2. To avoid damage to the equipment, do not share the protec-
tive conductor wiring with any other devices nor wire the
protective conductor terminal to the girder. Be sure to wire
the protective conductor of the equipment independently.
3. Keep the ground line as short as possible.
Содержание V530-R150
Страница 1: ...Cat No Z136 E1 1 V530 R150 OPERATION MANUAL 2 Dimensional Code Reader ...
Страница 2: ...V530 R150 2 Dimensional Code Reader Operation Manual Produced July 1999 ...
Страница 89: ...5 4 Section STEP 2 Setting Reading Conditions 79 8 Select 1 Read DataMatrix 9 Select Reading Settings ...
Страница 95: ...5 6 Section STEP 4 Starting Code Reading 85 3 Input reading trigger Reading is performed QRCode ABCDE12345 ...
Страница 132: ...6 2 Section SET Setting Mode 123 Line Bright X fixed Y coordinate Line Bright Y fixed X coordinate ...
Страница 197: ...Cat No Z136 E1 1 V530 R150 2 Dimensional Code Reader OPERATION MANUAL ...