Section
Regular Inspections
162
To maintain the V530-R150 in the best condition, perform the fol-
lowing regularly.
•
Lightly wipe off dirt with a soft cloth.
•
Clean the lens and indicators with a cloth for a lens or air brush.
Inspection Items
Details
Required Tools
Power Supply
The voltage measured at the power supply
terminals on the terminal block must be
24 VDC (+10%, –15%).
Circuit Tester
Ambient
Temperature
The operating ambient temperature inside the
cabinet must be between 0 to +50
°
C.
Thermometer
Ambient Humidity
The operating ambient humidity inside the
cabinet must be between 35 to +85%.
Hygrometer
Installation
Each cable connector must be correctly
inserted and locked.
The cameras must be firmly secured.
The camera lens mounts must be firmly
secured.
Phillips screw
driver
Note
1. Turn OFF the power and take safety precautions before
conducting inspections.
2. Do not use thinners or benzene.