6-2
Section
SET (Setting) Mode
119
Select
Data (0 to 3) to register the standard data and then
set to
ON.
OFF:
No judgment is performed. (Default setting)
Data 0 to 3: The data read in the next trigger is registered
as the number of standard data.
Verify:
Every time reading is performed, the regis-
tered standard data and reading data are veri-
fied.
The judgment result is output to terminal
blocks (DO0 to 3) and RS-232C (Normal).
Clr Data:
All registered data is cleared.
3
When Data History is turned ON, the following four items are
counted and displayed on the screen.
The counted values are maintained even when the power is
turned OFF if the data is saved in flash memory.
The values are cleared when OFF is selected. (The default
setting is OFF.)
•
Number of readings
•
Number of OK readings
•
Reading accuracy
(Number of OK readings
B
Number of readings
×
100)
•
Error codes
4
When Reading Accuracy is turned ON, one trigger performs
ten readings.
The reading accuracy and the data from the 10th reading
are displayed on a screen and output to RS-232C (Normal).
(The default setting is OFF.)
5
Measure L Length is a function that measures L length auto-
matically.
If this function is turned ON, press TRIG on the console
when in MON (monitor) or RUN mode to measure the L
length. The L length is measured and reflected in the
Read
DataMatrix/Reading Settings/Length of Finder setting
When setting reading conditions, use this function to set the
L length.
Turn OFF after setting the L length. (The default setting is
OFF.)
Содержание V530-R150
Страница 1: ...Cat No Z136 E1 1 V530 R150 OPERATION MANUAL 2 Dimensional Code Reader ...
Страница 2: ...V530 R150 2 Dimensional Code Reader Operation Manual Produced July 1999 ...
Страница 89: ...5 4 Section STEP 2 Setting Reading Conditions 79 8 Select 1 Read DataMatrix 9 Select Reading Settings ...
Страница 95: ...5 6 Section STEP 4 Starting Code Reading 85 3 Input reading trigger Reading is performed QRCode ABCDE12345 ...
Страница 132: ...6 2 Section SET Setting Mode 123 Line Bright X fixed Y coordinate Line Bright Y fixed X coordinate ...
Страница 197: ...Cat No Z136 E1 1 V530 R150 2 Dimensional Code Reader OPERATION MANUAL ...