![background image](http://html1.mh-extra.com/html/omron/v530-r150/v530-r150_operation-manual_741959024.webp)
!
2-3
Section
Power Supply and Ground
11
2-3-3
Wiring the Power Supply
WARNING
Use a DC power supply with safe extra low-voltage circuits on
the secondary side. Excessively high voltages can result in
electric shock.
Power supply
Use a power supply with the following specifications. We recom-
mend using OMRON’s S82K-01524 Power Supply.
Output current
0.6 A min.
Power supply voltage
24 VDC+10%, –15%
24 VDC
Note
1. Wire the Power Supply Unit independently of other devices.
In particular, keep the power supply wired separately from
inductive loads.
2. Keep the power supply cable as short as possible.
3. If UL recognition is required, use a UL class II power supply.