6-5
Section
System
144
4
Set the time from when the result is output to the terminal
block to when the GATE signal is turned ON. This time is
used to wait until the data output becomes stable. Set a time
between 1.0 and 1000.0 ms that is longer than the delay
time for the external device.
(The default setting is 1.0 ms.)
5
Set the time during which the GATE signal is ON. Set a value
between 1.0 and 1000.0 ms so that the external device can
read the reading judgment. (The default setting is 5.0 ms.)
Operational Procedures for RS-232C, Normal, Host Link and Terminal
Block
Procedure
1
Select
Communications.
Image storage
Backup
Startup mode
Multi drop
Error method
Version
Communications
System settings
2
Select
RS-232C, Normal, Host link, or Terminal block.