5-3
Section
Monitoring and Changing I/O Signals
45
2. Change the display using the Up and Down Keys.
CS1W-MC221/421, CV500-MC221/421
C200H-MC221
MON| XYZU
IN |DRV ALRM0010
|STOP 0010
|
DRV alarm: Driver alarm input
MON| XY
IN |DRV ALRM 00
|STOP 00
|
CS1W-MC221/421, CV500-MC221/421
C200H-MC221
MON| 1234
IN |GET IN 0010
|
|2
GET IN: General-purpose inputs
MON| 12
IN |GET IN 00
|
|B
Procedure 2
Use the following procedure to monitor the output signals.
1, 2, 3...
1. With the last screen of Procedure 1 displayed, press the Down Key.
CS1W-MC221/421, CV500-MC221/421
C200H-MC221
MON| XYZU
OUT|RUN COM 0010
|ALM RSET0000
|SENSR ON1111
MON| XY
OUT|RUN COM 00
|ALM RSET 00
|SENSR ON 11
2. Change the display using the Up and Down Keys.
CS1W-MC221/421, CV500-MC221/421
MON| 1234
OUT|GET OUT 0010
|
|
GET OUT: General-purpose outputs
There are no general-purpose
outputs for the C200H-MC221.
Procedure 3
Use the following procedure to monitor the analog outputs.
With the last screen of the Procedure 2 displayed, press the Down Key.
CS1W-MC221/421, CV500-MC221/421
C200H-MC221
MON|X 10.0
D/A|Y* 10.0
|Z 1.0
|U Ć10.0
Analog output status is displayed in the range between –10.0 V and +10.0 V.
MON|X 10.0
D/A|Y* 10.0
|
|
Procedure 4
Use the following procedure to change the output signals.
1, 2, 3...
1. After selecting the output signal from the MONITOR mode display, press the
CHG Key.
CS1W-MC221/421, CV500-MC221/421
C200H-MC221
MON| XYZU
OUT|RUN COM 0010
|ALM RSET0000
|SENSR ON1111
MON| XY
OUT|RUN COM 00
|ALM RSET 00
|SENSR ON 11
CHG