2-3
Section
Restricted Functions
18
2-3
Restricted Functions
Some Teaching Box functions are restricted depending on the control mode of
the MC Unit.
The following tables show which functions are valid for each control mode.
CS1W-MC221/421
Function
Control mode
T.BOX
LIMITED
T.BOX
ENABLED
T.BOX
RESERVED
Monitoring
Current position
OK
OK
OK
g
I/O signals
See note 1
OK
OK
Error data
OK
OK
OK
Position data
See note 2
OK
OK
Z-phase tolerance
OK
OK
OK
Servo parameters
OK
OK
OK
Origin searches
No
OK
OK
Program execution
No
OK
OK
Jogging
No
OK
OK
MPG (handle feeding)
No
OK
OK
Extension
Change mode
OK
OK
OK
Servo-lock/
Servo-unlock
No
OK
OK
Memory protection
No
OK
OK
Absolute origin
setting
No
OK
OK
Message switching
OK
OK
OK
Saving
No
OK
OK
Override
See note 3
OK
OK
Teaching
No
OK
OK
Deceleration stop
No
OK
OK
Error reset
No
OK
OK
Note
1. Only monitoring of the ON/OFF status of output signals and monitoring of
analog output data is possible. No changes can be made.
2. Only monitoring of position data is possible. No changes can be made.