16
Chapter
1
Ra
tings
F3SJ-A
User’s Manual
Overview and Specifications
Material
Casing (including metal parts on both ends): Aluminum, zinc die-cast
Cap: ABS resin
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
Weight
(
packaged
)
- F3SJ-A
P14
Weight (g)=(protective height) x 1.7+
α
- F3SJ-A
P20/F3SJ-A
P25/F3SJ-A
P30
Weight (g)=(protective height) x 1.5+
α
- F3SJ-A
P55
Weight (g)=(protective height) x 1.4+
α
The values for
α
are as follows:
When protective height is between 245 and 596mm,
α
=1100
When protective height is between 600 and 1130mm,
α
=1500
When protective height is between 1136 and 1658mm,
α
=2000
When protective height is between 1660 and 2180mm,
α
=2400
When protective height is between 2195 and 2500mm,
α
=2600
Accessories
Test rod *1, instruction sheet, top and bottom mounting brackets, intermediate mounting
brackets *2, error mode label, user’s manual (CD-ROM)
*1 It is not included in F3SJ-A
P55.
*2 The number of intermediate mounting brackets depends on the total length of the F3SJ.
- F3SJ total length is from 600 to 1,130mm: 1 set for each the emitter and receiver is included
- F3SJ total length is from 1136 to 1,658mm: 2 sets for each the emitter and receiver are
included
- F3SJ total length is from 1660 to 2,180mm: 3 sets for each the emitter and receiver are
included
- F3SJ total length is from 2195 to 2500mm: 4 sets for each the emitter and receiver are
included
Applicable standards
IEC61496-1, EN61496-1, UL61496-1 Type 4ESPE (Electro-Sensitive Protective Equipment)
IEC61496-2, prEN61496-2, UL61496-2 Type 4AOPD (Active Opto-electronic Protective
Devices)
IEC61508, EN61508 SIL3