90
Ch
apt
e
r
3
Set
ting Adjust
ed
to Appl
ication
F3SJ-A
User’s Manual
What can be done by the setting tool
Time t1 [ s ] for F3SJ to enter muting state is within a range shown below:
t1 < T1max. . . . . . . . . . . Equation (5)
T1max [ s ] : Muting input time limit value (maximum)
The PC tool for F3SJ can change T1max.
Timing Chart
*1 The value is applied to a single sensor. Values for connected sensors are:
•T1max : Muting input time limit value (maximum)
Maximum time difference between muting inputs 1 and 2.
•T2 : Muting time limit
Time to be continued for muting function. If muting state exceeds this time, the function is canceled.
•T3 : Maximum muting input time with allowable waveform cracks
This is the maximum time limit allowed for waveform cracks for muting input 1 and muting input 2
when muting is in effect. It is set as 0.1s.
# of connections
*1 Value (s)
Single
0.15
2 connected
0.26
3 connected
0.29
4 connected
0.32
Muting input 1
(Limit switch1)
ON
OFF
Muting input 2
(Limit switch2)
F3SJ Unblocked
/Blocked
Unblocked
Blocked
Safety output
ON
OFF
ON
OFF
Enabled
Disabled
Muting lamp
Blinking
OFF
T1max
Muting state
T2 max.
0.15s max. *1
T3 (0.1s) max.
T3 (0.1s) max.
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com