27
F3SJ-A
User’s Manual
Chapter
2
Ba
si
c Sys
te
m
System Configuration and Functions
E
Basic System
Basic system indicates the F3SJ with its default factory settings.
The basic system provides basic safety light curtain functions. Most functions can be used without performing
additional configuration.
Wiring Diagrams
Wiring using manual reset mode, external device monitoring function
S1
S2
K1, K2
K3, K4
: External test switch (connect to 0V if a switch is not required)
: Interlock/lockout reset switch
: Relay or other device that controls hazardous parts of the machine
: Load or PLC, etc. (for monitoring)
*1 Use a switch for micro loads (Input specifications: 24V, 1.8mA)
*2 F3SJ can operate even if K3 and K4 are not connected
Interlock selection input (White)
(Grey) Communication line (+)
(Pink)
Communication line (-)
0V(Blue)
0V(Blue)
Shield
Shield
Test input(Green)
Reset input(Yellow)
24V(Brown)
24V(Brown)
External device monitoring input (Red)
Auxiliary output 1(Yellow)
Safety output 1(Green)
Safety output 2(White)
Auxiliary output 2(Red)
S1
S2
*1
*1
*2
*2
Emitter
Receiver
K4
K3
K2
K1
K1
K2
0V
Power
supply
+24V DC