What can be done by the setting tool
E
Available range for floating
0
10
20
30
40
50
60
Number of floating beams : 4 Number of Allowable beams : 2
Number of floating beams : 4 Number of Allowable beams : 3
Number of floating beams : 3 Number of Allowable beams : 2
Interrupting object diameter [mm]
Available range for setting
40
20
20
35
55
55
F3SJ-A
P20 series
Available range for floating
0
10
20
30
40
50
60
70
80
Number of floating beams : 4 Number of Allowable beams : 1
Number of floating beams : 4 Number of Allowable beams : 2
Number of floating beams : 3 Number of Allowable beams : 1
Number of floating beams : 3 Number of Allowable beams : 2
Number of floating beams : 2 Number of Allowable beams : 1
Interrupting object diameter [mm]
Available range for setting
25
25
45
35
55
55
45
75
65
75
F3SJ-A
P25 series
Available range for floating
0
10
20
30
40
50
60
70
80
90
100
Number of floating beams : 4 Number of Allowable beams : 1
Number of floating beams : 4 Number of Allowable beams : 2
Number of floating beams : 3 Number of Allowable beams : 1
Number of floating beams : 3 Number of Allowable beams : 2
Number of floating beams : 2 Number of Allowable beams : 1
Interrupting object diameter [mm]
Available range for setting
30
30
55
45
70
70
55
95
80
95
F3SJ-A
P30 series
Available range for floating
0
20
40
60
80
100 120 140 160 180 200
Number of floating beams : 4 Number of Allowable beams : 1
Number of floating beams : 4 Number of Allowable beams : 2
Number of floating beams : 3 Number of Allowable beams : 1
Number of floating beams : 3 Number of Allowable beams : 2
Number of floating beams : 2 Number of Allowable beams : 1
Interrupting object diameter [mm]
Available range for setting
55
55
105
95
145
145
105
195
155
195