F3SJ-A
User’s Manual
Overview and Specifications
Internal Indicator for Muting System
Shown below are internal indicator statuses while the keycap for muting is being attached.
For an explanation of terminology such as function names, refer to the glossary.
7
OFF-state indicator
OFF
ON
Turns ON when safety outputs are
OFF
.
Blinking Blinks at following states:
- Lockout state
- One or more beams are blocked during the maintenance status
8
ON-state indicator
ON
ON
Turns ON when safety outputs are ON.
Blinking Blinks when no beams are blocked during the maintenance
status
9
–
–
–
–
10
–
–
–
–
No.
Indicators
ON/
Blinking
Description
1
Incident light level
indicator
LEVEL-1 to 5
ON
Indication status of LEVEL-1 to 5 shows the incident light level
status of the F3SJ.
2
Error mode indicator
ERROR-A to C ON/
Blinking
Turns ON or blinks only when the F3SJ enters lockout, and the
cause of the error is indicated by the status of ERROR-A to C
indicators.When F3SJ are series-connected, the error mode
indicator lamps turn ON or blink according to the details of each
error. Affix the error mode label (included) near the F3SJ to
allow for quick troubleshooting when errors occur. For details of
the error mode, see "Chapter 7 Troubleshooting".
3
Power indicator
POWER
ON
Turns ON while the power is ON.
Blinking Blinks during maintenance status.
4
Interlock indicator
INTLK
ON
Turns ON when F3SJ is in interlock state.
Blinking Blinks when in lockout.
5
Muting input 1 indicator
MUTE1
ON
Turns ON when an input is given to muting input 1.
Blinking Blinks during muting/override.
6
Muting input 2 indicator
MUTE2
ON
Turns ON when an input is given to muting input 2.
Blinking Blinks during muting/override.
7
OFF-state indicator
OFF
ON
Turns ON when safety outputs are
OFF
.
Blinking Blinks at following states:
- Lockout state
- One or more beams are blocked during the maintenance status
8
ON-state indicator
ON
ON
Turns ON when safety outputs are ON.
Blinking Blinks when no beams are blocked during the maintenance
status
9
Muting error indicator
MUTING
ERROR
ON
Turns ON when a muting error occurs.
10
Blanking/Test indicator
BLANKING/
TEST
ON
Turns ON when the blanking function is enabled.
Blinking Blinks when external test is being performed.