What can be done by the setting tool
E
Status Information Display
Overview
Provides readout of F3SJ’s I/O information and status. This function is for the PC tool for F3SJ only.
Functional Description
F3SJ’s I/O information and status can be read out by the PC tool for F3SJ.
Setting Change
Configure in a bulk in case of a series connection. (to be written into the primary sensor only)
Information available to read
*1 When the F3SJ is in maintenance status, the actual safety output does not turn ON even when the
output status of the safety output is ON.
Function
Initial Setting
Available Setup Item
Setting Console
PC Tool For F3SJ
Status Monitor
Read only
–
3
F3SJ Status
Description
Test Input
Linked to test input
Reset Input
Linked to reset input
Interlock Selection Input
Linked to interlock selection input
Muting Input 1
Linked to muting input 1 (for a muting system)
Muting Input 2
Linked to muting input 2 (for a muting system)
Safety Output 1 *1
Linked to safety output 1
Safety Output 2 *1
Linked to safety output 2
Auxiliary Output 1
Linked to auxiliary output 1
Auxiliary Output 2
Linked to auxiliary output 2
External Indicator (Emitter)
Linked to external indicator output 1
External Indicator (Receiver)
Linked to external indicator output 2
Incident Light Level Indicator
Indicates light intensity level indicator
Interlock state
Displayed when in interlock
Source Voltage
Indicates supplied source voltage
Muting state
ON when muting
Muting error state
ON when there is a muting error
Override state
ON when in override
Blanking beam incidence state
ON when blanking beam is incident
Light level diagnosis information
When F3SJ is ON and the incident light level is 130% or less of
the ON threshold value for 10 seconds or more