Wiring
FQ2-S4 User’s Manual
2
Install
a
tion an
d
C
onn
ecti
ons
43
I/O Signal Circuit Diagrams
Preventing Chattering
• The Sensor is equipped with an anti-chattering function, but if the chattering is 100
µ
s or longer, a faulty input may
occur. (Input signals of 99
µ
s or shorter are ignored. Signals of 100
µ
s or longer are treated as input signals.)
• Use no-contact output devices (e.g., SSR or PLC transistor output) for the input signals. If contacts (e.g., relay) are
used, chattering may cause the trigger to be input again during execution of a measurement.
Power Supply Specifications When a Switching Regulator Is Connected
Use a power supply that meets the following specifications. (The power supply is sold separately.)
Supply power from a DC power supply for which measures have been applied to prevent high voltages (e.g., a safety
extra low voltage circuit).
If UL certification is required for the overall system, use a UL Class II DC power supply.
Attaching the LED Warning Label
Attach the enclosed LED warning label to the cable or other location. The LED warning label must be attached
to a location that is readily visible from the Sensor.
Item
Description
FQ2-S4
@@@@@
FQ2-S4
@
-
@@@
Power supply voltage
24 VDC (21.6 to 26.4 V)
Recommended Power Supply
S8VS-06024
@
(24 VDC, 2.5 A)
S8VS-01524
@
(24 VDC, 0.65 A)
External power supply terminal screws
M4 (tightening torque: 1.2 N·m)
GND (0V)
OUT0 (OR)
OUT1 (BUSY)
OUT2 (ERROR)
TRIG
IN0
IN1
IN2
IN3
IN4
IN5
IN0
IN1
IN2
IN3
IN4
IN5
TRIG
GND (0V)
OUT0 (OR)
OUT1 (BUSY)
OUT2 (ERROR)
PNP
NPN
Brown Power supply (24 VDC)
24 VDC
Yellow
Blue
Load
Purple
White
Black
Red
Orange
Light blue
Green
Gray
24 VDC
Pink
Blue
Yellow
Internal circuits
Internal circuits
Purple
White
Light blue
Red
Green
Orange
Black
Gray
Load
Pink
Brown Power supply (24 VDC)
Important
Important
Attachment Example
Warning Label
Warning Label
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......