Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
316
FQ2-S4 User’s Manual
Changing the Settings of the I/O Signals
Changing the Settings of the Output Signals
●
Adjusting the Judgement Output Timing
You can change the timing of outputting the measurement result with the OR signal (after finalizing the
measurement result) according to the needs of the external device.
Adjusting the Judgement Output Timing: p. 288
●
Changing the Judgement Output ON Conditions
You change the ON condition for the OR signal to turn ON the signal when the judgement result is OK or when
it is NG.
Changing the Judgement Output ON Condition: p. 290
●
Adjusting the End Timing of the BUSY Signal
You can change the end timing of the BUSY signal.
Adjusting the Judgement Output Timing: p. 290
●
Changing the Output Polarity of the Output Signals
You can change the ON/OFF output polarity of the output signals
[In/Out]
−
[I/O setting]
−
[I/O]
−
[Output]
1
Press [Output polarity] and select the ON/OFF polarity for all output signals.
●
Setting the Output Time of the ACK Signal
You can set the output time of the normal execution completion signal for parallel commands.
[In/Out]
−
[I/O setting]
−
[I/O]
−
[Output]
−
[ACK signal ON period]
The ACK signal is not output for normal completion of continuous measurement commands.
●
Changing the Output Timing and Output Time of the STGOUT Signal
You can change the output settings of the STGOUT signal to adjust when and for how long the external lighting is lit.
Item
Parameter
Description
Output polarity
Positive (default)
Negative
You can reverse the ON/OFF conditions of the output signals.
For example, when the BUSY signal uses positive polarity, the signal is ON
while the Sensor is processing something. If you change the setting to
negative polarity, the Sensor will be ready to receive data or signals when
the BUSY signal is ON.
Applicable Output Signals
• RUN
• OR
• BUSY
• ERROR
• STGOUT
• SHTOUT
• DSA
• GATE
• D0 to D15
• ACK
Important
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......