
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2-S4 User’s Manual
313
8
Controll
ing
Ope
rati
on a
nd Outputting
Data
wi
th
a
Para
llel
Co
nne
ctio
n
●
Timing Chart
Example: Three Data Items Set for Parallel Data Output
1
Turn ON the TRIG signal while the BUSY signal is OFF.
2
Measurement begins and the BUSY signal is turned ON during the measurement process.
3
When the measurement has been finished, the measurement result is output using an OR signal,
and the BUSY signal is turned OFF.
*1
*1
You can also set the [BUSY output] parameter so that the BUSY signal is turned OFF after the completion of data logging, image logging,
or displaying results.
4
Turn ON the DSA signal from the external device to request data transmission after you have
confirmed that the BUSY signal is OFF.
*2
*2
If you do not turn ON the DSA signal within the specified timeout time after measurements are completed, a timeout error will occur. (This
is timeout time 1.)
5
When the DSA signal turns ON, the D0 to D31 signals are output and the GATE signal is turned
ON.
6
When the DSA signal is turned OFF, the GATE signal turns OFF.
*3
*3
If you do not turn OFF the DSA signal within the specified timeout time after the GATE signal turns ON, a timeout error will occur. (This is
timeout time 2.)
7
If more than one data item is being output for one measurement and you do not turn ON the DSA
signal within the specified timeout time after the GATE signal turns OFF, a timeout error will oc-
cur. (This is timeout time 3.)
If the DSA signal does not turn ON
within the specified time after
measurements are completed, a
timeout error will occur.
If more than one data item is being output for one
measurement and the DSA signal does not turn
ON within the specified time after the GATE
signal turns OFF, a timeout error will occur.
If the DSA signal does not turn OFF within the specified time
after the GATE signal turns ON, a timeout error will occur.
Overall judgement (Output when measurements have been
completed regardless of the DSA signal.)
Data 0
Timeout Time 1
Timeout Time 3
Timeout Time 2
Data 1
GATE
ON delay
TRIG signal
OFF
ON
OFF
ON
ON for 1 ms min.
BUSY signal
OFF
ON
OFF
ON
OR signal
GATE signal
OFF
ON
DSA signal
ON while measurements are being processed
(depends on BUSY output conditions)
Run Mode entered.
RUN signal
Setup Mode entered.
Data 2
D0 to
D15
signals
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......