External Reference Parameters
FQ2-S4 User’s Manual
515
Ap
pend
ices
12
*1
Use the ITEMDATA2 command to set and/or acquire a text string.
131
Mea-
sure-
ment
result
Code type
Settings/
Acquisition
0: Data Matrix
1: QR Code
2: MicroQR Code
3: PDF417
4: MicroPDF417
0
---
---
132
Timeout time (ms)
Settings/
Acquisition
1 to 9999
9999
---
---
133
Reverse (Data Matrix,
QR Code, Micro QR
Code only)
Settings/
Acquisition
0: Normal
1: Reverse
0
---
---
134
Code color (Data
Matrix, QR Code, Micro
QR Code only)
Settings/
Acquisition
0: Black
1: White
2: Auto
2
---
---
135
Shape (DataMatrix
only)
Settings/
Acquisition
0: Square
1: Square or Rect.
0
---
---
150
Verifica-
tion con-
dition
Selected master num-
ber
Settings/
Acquisition
0 to 31
0
---
---
152
Auto master data num-
ber
Setting/Acqui-
sition
0 to 31: Master data num-
ber
−
1: OFF
−
1
---
---
170
Output
parame-
ter
String output ON/OFF
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON
0
---
---
171
NG error code output
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON
1
---
---
172
Partial output ON/OFF
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON
0
---
---
173
Output end digit (mem-
ory link)
Setting/Acqui-
sition
1 to 128
128
---
---
174
Output beginning digit
(memory link)
Setting/Acqui-
sition
1 to 128
1
---
---
202+3N
(N=0 to
31)
*1
Verifica-
tion con-
dition
Master data N
Settings/
Acquisition
32 characters max.
None
---
---
300+N
(N=0 to
31)
Reference unit number
N
Setting/Acqui-
sition
0 to 31
0
---
---
410
Logging
condi-
tions
Data logging switch for
unit
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
411
Data logging switch for
judgement
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
412
Data logging switch for
number of characters
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
500
Display
setting
Number of characters
display
Setting/Acqui-
sition
0: OFF
1: ON
1
---
---
501
Character display
Setting/Acqui-
sition
0: OFF
1: ON
1
---
---
External
refer-
ence
number
Category Data name
Setting/Acqui-
sition
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......