External Reference Parameters
FQ2-S4 User’s Manual
519
Ap
pend
ices
12
*1 To acquire the detected text string, use the ITEMDATA2 command.
OCR
410
Logging
condi-
tions
Data logging switch for
unit
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
411
Data logging switch for
judgement
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
412
Data logging switch for
number of characters
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
413
Data logging switch for
cell recognition rate
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
414
Data logging switch for
contrast
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
415
Data logging switch for
focus
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
501
Display
setting
Character display
Setting/Acqui-
sition
0: OFF 1: ON
1
---
---
502
Cell recognition rate
display
Setting/Acqui-
sition
0: OFF 1: ON
1
---
---
503
Contrast display
Setting/Acqui-
sition
0: OFF 1: ON
1
---
---
504
Focus display
Setting/Acqui-
sition
0: OFF 1: ON
1
---
---
External
refer-
ence
number
Category
Data name
Setting/Acquisition
Data range
Default
Expres-
sion text
string
Logged
data/
Judge-
ment
parame-
ter
0
Measurement
result
Judgement
Acquisition only
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error,
−
16: Measurement timeout error,
−
17: Format not entered error
−
2
JG
Logged
data
5
Index number
Acquisition only
−
2: Verification result is OFF or read
was NG,
−
1: Verification result is NG
0 to 31: Master data number
−
2
IN
Logged
data
6
Number of charac-
ters
Acquisition only
0 to 128
0
N
Logged
data
7
Read character
string
Acquisition only
128 characters max.
0
--
---
8
Similarity
Acquisition only
0 to 100
0
SIM
Logged
data
9
Stability
Acquisition only
0 to 100
0
STB
Logged
data
103
Output parame-
ter
Reflect
Setting/Acquisition
0: Yes, 1: No
0
---
---
External
refer-
ence
number
Category Data name
Set/acquired
Data range
Default
Text string
assigned
to
Ethernet
output
setting
Logged
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......