Inspecting with the Edge Width Inspection Item
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
171
Changing Edge Detection Conditions (Sensors with Monochrome Cameras Only)
You can change the measurement conditions for Sensors with Monochrome Cameras. Change the [Density
change] and [Measurement method] parameters.
Reflect in Total Judgement
You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Edge Width]
−
[Details] Tab Page
−
[Output parameter]
Unstable Edge Width Results (Sensors with Color Cameras)
If the measurement result is not stable, adjust the [Edge level], [Noise level], and [Set color.] parameters.
Increasing Edge Width Processing Speed
Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 144
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be output to external devices or used in calculations as measurement data.
4-17 Calculations and Judgements Using Inspection Item Data: p. 197
• You can change the output form for each measurement value to one of the following settings.
Press
[
]
−
[Result type] on the right of the display.
Absolute value (default): The measured edge width is output.
Relative value: The difference from the reference value is output.
Ratio: The percentage of the reference value is output.
Expression text string
Data name
Description
Data range
JG
Judgement
This is the judgement result.
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error
W
Edge width
Edge width
0 to 99999.9999
SW
Ref. edge width (reference
edge width)
This is the reference edge width from
when the model was registered.
0 to 99999.9999
DF
D. edge width (difference in
edge width)
This is the difference between the ref-
erence edge width and the measured
edge width.
0 to 99999.9999
Note
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......