Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
442
FQ2-S4 User’s Manual
Setting the Inspection Item Data: 280F 00501020
This command sets the parameters and measurement values of the specified inspection item.
●
Format
●
Response Format
●
End Codes
●
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Inspection item number (4 bytes) External reference
number (4 bytes)
Set value (4 bytes)
28
0F
00501020
Inspection item number from 00
to 1F (2 digits max.)
External reference
number
Set value (1,000
times the actual
value)
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28
0F
End code
00501020
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Inspection item number
Specifies the number of the inspection item to set.
External reference num-
ber
Specifies the external reference number.
12-2 External Reference Parameters: p. 491
Setting
Specifies the set value.
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......