11-1 Error Histories
Error histories are stored with the PC Tool and in the Sensor and in the Touch Finder.
Up to 100 errors will be stored in the error history in the Sensor or Touch Finder.
Errors Stored in the Error History
Note:
If an error that is indicated by this icon occurs, the ERROR operation indicator will light and the ERROR signal will turn ON.
Error in error history
Cause
Points to check
Measures to perform
TRIG Input Error
(Error code: 01040302)
A TRIG signal was input when
the BUSY signal for Sensor
measurement was ON.
• Check the program in the PLC
or other host to see if an inter-
lock or similar measure has
been implemented.
• If a relay or other device with
contacts is being used as the
input device, see if chattering
has occurred.
• Program interlocks to control
the TRIG so that they do not
turn ON while the BUSY signal
is ON.
• Switch from a device with con-
tacts (e.g., relay) to a device
without contacts (e.g., SSR or
PLC transistor output).
IN Input Error
(Error code: 11020900)
A no-protocol command or PLC
link command was input when
the BUSY signal was ON.
• Is an interlock or other counter-
measure provided, e.g., in a
ladder program in the PLC?
• Program interlocks, such as in
a ladder program, so that no-
protocol commands and PLC
link commands are not input
while the BUSY signal is ON.
Scene Data Error
(Error code: 01030800)
The scene data to switch to is
corrupted.
---
The scene data to be switched
to is corrupted.
Reset the scene data from the
beginning.
Model Error
(Error code: 01050405 or
01050500)
A model was re-registered with
an image with low contrast.
Check the image to see if the
contrast is too low to register the
model.
Increase the image contrast and
try again to register the model.
Logging Error
(Error code: 02160702 or
02160703)
Some data was not saved when
logging data to files on an SD
card.
Check to see if the BUSY output
parameter is set to
Measurement
.
Set a sufficiently long measure-
ment interval or set the BUSY
output condition to [Data logging]
or [Image logging].
Communications error
(Error code: 01010100)
Normal EtherNet/IP communi-
cations became impossible after
they were established.
Check to see if communications
were cut off with the data link
partner device and to see if a
cable is broken.
Check the cable connection to the
data link partner device.
EtherNet/IP communica-
tions error (Error code:
01010101)
A timeout occurred in process-
ing to output the measurement
results via EtherNet/IP.
Make sure that handshake pro-
cessing is being performed by the
master. Also, make sure that the
measurement interval is long
enough.
Check the measurement interval
and handshake processing.
Change the timeout time so that it
is suitable for the ladder program
processing time.
Output buffer error
(Error code: 01010701)
An output data buffer overflow
occurred during output process-
ing of measurement results for
PLC Link or EtherNet/IP.
• Check the measurement inter-
val to see if it is long enough.
• Make sure that handshake pro-
cessing is being performed by
the master.
Check the measurement interval
and handshake processing.
SD card output error
(Error code: None)
A write to the SD card failed.
An attempt was made to save
more data than the available
space on the SD card.
Check to see if the SD card is
locked. Check to see if there is
sufficient space available on the
SD card.
Unlock the SD card. Delete
unnecessary files from the SD
card.
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......