Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
290
FQ2-S4 User’s Manual
When one-shot output is selected as the output mode, make the following value smaller than the trigger input
period.
• One-shot delay time + One-shot output time
Changing the Judgement Output ON Conditions
The ON condition for the OR signal or the OR0 to OR31 signals can be set to be output when the judgement
results are OK or when they are NG. The default setting is when they are NG.
Settings
[In/Out]
−
[I/O setting]
−
[I/O setting]
−
[Output]
−
[OR output]
Changing the Polarity of the BUSY Output
The Sensor turns ON the BUSY output signal during measurements and other processing to indicate that a
measurement trigger cannot be received. The polarity of the BUSY signal can be reversed so that it is ON only
when a trigger signal can be received.
In the default settings, the BUSY signal is assigned to OUT1. If you change the assignment of the BUSY signal,
change the polarity of the corresponding output.
Settings
[In/Out]
−
[I/O setting]
−
[I/O setting]
−
[Output]
−
[OUT1 Polarity]
All timing charts in this manual show the operation of the BUSY signal with positive polarity (the default
setting). If you change the polarity of the BUSY signal, take this into consideration when reading the timing
charts.
Item
Description
Output mode
One-shot output
After the measurement results are finalized, if the judgement output ON condition
is met, the OR signal is turned ON for the one-shot output time. It is then turned
OFF once the specified time has expired.
Level output (default)
The judgement is output after measurement results are finalized and the ON/OFF
status of the OR signal is held until it is changed for the next measurement result.
Output delay
When one-shot output mode is selected, this parameter sets the delay from when
a measurement is completed until when the OR signal turns ON. (Setting range: 0
to 1,000 ms)
Output time
When one-shot output mode is selected, this parameter sets the time that the OR
signal is ON. (Setting range: 1 to 1,000 ms)
Item
Description
OR output
OK: ON
The output is turned ON if the judgement is OK.
For the overall judgement, the output is turned ON if all judgements are OK.
NG: ON (default)
The output is turned ON if the judgement is NG.
For the overall judgement, the output is turned ON if even one judgements is NG.
Item
Description
OUT1 Polarity
Positive (default)
The BUSY signal is ON while the Sensor is processing data.
Negative
The BUSY signal is ON while the Sensor can receive a trigger signal.
Important
Important
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......