39
F3SJ-A
User’s Manual
Chapter
2
Mu
ting Sys
te
m
System Configuration and Functions
E
To enable the muting function, D1 and d1 must satisfy formulas (1) and (2), respectively.
This distance must prevent the muting function from being enabled by a person passing through the
muting sensors.
Also, install the F3SJ and muting sensors so that a workpiece passes through all muting sensors
before the next workpiece arrives at the muting sensors.
Wiring Diagrams
Timing chart
+24V DC
A1
B1
1
8
(White) Muting input 1
(Red) Muting input 2
T2
T1
0.1s
Muting sensor A1
ON
OFF
Muting sensor B1
ON
OFF
Safety output
ON
OFF
ON
OFF
Muting function
Enabled
Disabled
T1: Muting input time limit
T2: Muting time limit
Muting lamp
(external indicator)
0.1s max.
0.1s max.
F3SJ Unblocked
/Blocked
Unblocked
Blocked
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles