*1. Indication patterns and incident light levels of the incident light level indicator
Operation is possible with incident light level of 100% or more, but to ensure stability, operate when all incident light level
indicators
*2. Indication patterns of error mode indicator and causes of errors
8
ON-state indicator (ON)
Turns ON when safety outputs are ON.
9
Muting error indicator
(MUTING ERR)
ON
Not used
Turns ON when a muting error occurs.
Blinking Not used
Not used
10
Test indicator (TEST)
ON
Not used
Not used
Blinking Not used
Blinks when external test is being
performed.
Incident light level
170% or higher of safety output ON level
From 130 to 170% of safety output ON level
From 100 to 130% of safety output ON level
From 75 to 100% of safety output ON level
From 50 to 75% of safety output ON level
Less than 50% of safety output ON level
Cause of error
Incorrect wiring or breakage of interlock selection input line or reset input
line.
Relay is welded or recovery time is too long. Incorrect wiring or breakage of
external device monitoring line.
Incorrect wiring of safety output 1 or 2. Failure of safety output circuit.
Incorrect wiring or breakage of series-connection cable.
Effect of noise. F3SJ Failure of internal circuit.
Breakage, incorrect wiring of communication line, disconnection of series
connection cable, influence of noise, or other errors.
Mutual interference or disturbance light.
Emitter and receiver have different F3SJ model names or number of series
connections.
Muting wiring failure.
End cap is not attached. Failure of internal circuit of F3SJ.
No.
Indicators
Description
For basic system
For muting system
ON OFF
OFF Blinking ON