95
F3SJ-A
User’s Manual
Chapter
4
Wiring Examp
le
s
Input/Output Circuit and Applications
E
Connecting to a G9SA-300-SC
•Reduced wiring due to connector connection
F
KM1
KM2
14 24 34
M
K3 K1 K3 K2
K1
K2
K3
K1
K2
K3
K3
E2
E1
D2
D1
C1
GND
Vcc
S1
+DC24V
0 V
E1
KM1
KM2
S2
Vcc
J1
A1 A2 T11 T12 H1
Y1 X1
13
23 33
GND
G1
T21
T22
KM1
KM2
Receiver
Emitter
Test
Receiver
Emitter
(Note 2)
Safety output
Safety output
Master select
Model G9SA-300-SC
KM1,KM2 N.C. contact
Unblocked
Blocked
Interlock reset switch
(S1)
Safety output 1, 2
K1,K2 N.O. cotact
KM1,KM2 N.O. cotact
K1,K2 N.C. contact
External test switch
(S2)
K3 N.O. cotact
K3 N.C. contact
S1
:Interlock reset switch
S2
:External test switch
(open between Vcc and J1 if a switch is not required)
KM1, KM2 :Magnetic contactor
M :3-phase
motor
E1
:24V DC power supply (S82K)
Note 1) F3SJ's external device monitoring and auxiliary output cannot be used.
Note 2) S2 performs normal operation when opened and external test when short-circuited.
Note 3) Do not connect any cable to terminals C1, D1, D2, E1, and E2
Model F39-JC C-L
Model F39-JC C-D
Sync
2-
Sync
2+
Sync
2-
Sync
2+
- F3SJ settings
- Auto reset mode
- Not using external device monitoring
- G9SA-300-SC settings
- Manual reset mode
- Using feedback loop
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles