84
Ch
apt
e
r
3
Wi
ring
F3SJ-A
User’s Manual
Wiring/Installation
Internal wiring diagram (F39-JC
B-L, F39-JC
B-D)
If the length of the F39-JC
A cable with connector on one end is insufficient, use 1 or more F39-
JC
B cable with connectors on both ends to extend the length, as required.
Connection example
Cable with connectors on both ends: Cable for connection with G9SA-300-SC (F39-
JC
C, sold separately)
Set model name
*1
For emitter
For receiver
L (mm)
F39-JCR2C
F39-JCR2C-L
Grey cable
F39-JCR2C-D
Black cable
200
F39-JC1C
F39-JC1C-L
F39-JC1C-D
1000
F39-JC3C
F39-JC3C-L
F39-JC3C-D
3000
F39-JC7C
F39-JC7C-L
F39-JC7C-D
7000
F39-JC10C
F39-JC10C-L
F39-JC10C-D
10000
F39-JC15C
F39-JC15C-L
F39-JC15C-D
15000
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
White
Brown
Green
Yellow
Grey
Pink
Blue
Red
Shield
Female
Connected to single-end connector cable, Cable
with connectors on both ends, Controller F3SP-B1P
White
Brown
Green
Yellow
Grey
Pink
Blue
Red
Shield
Male
Twisted pair wires are white and red, brown and blue, green and yellow, and grey and pink
Connected to connection cable and
Cable with connectors on both ends
Emitter
Receiver
Cable is grey
Cable is black
Model F39-JC A-D(Black)
Model F39-JC B-L(Grey)
Model F39-JC
A-L(Grey)
Cable with connectors on both ends
Model F39-JC
Cable with connector on one end
Model F39-JC A
Model F39-JC B-D(Black)
M12
39.5
L
43
(Unit: mm)
Body color: Grey
Body color: Grey
M12 Waterproof connector
M12 Waterproof connector
Vinyl-insulated round cable: Diameter 6.6
8-wire (4-pair) (Cross section of conductor: 0.3mm
2
/ Insulator diameter: 1.15mm)
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles