36
Chapter
2
Mu
ting Sys
te
m
F3SJ-A
User’s Manual
System Configuration and Functions
Ref.: Minimum wiring required to check the operation of the F3SJ when using the
muting function
(Wiring that does not use the external device monitoring function)
Installation standard for muting sensors
•Set the muting sensors so that they can detect all of the passing detection objects (palettes,
automobiles, etc.). Do not install in a position so that only the front or rear end of the detection object
is detected.
•Set the muting sensors so that they detect the objects even when they are loaded on palettes or other
transport devices.
•Also, install the F3SJ and muting sensors so that each object passes through all muting sensors
before the next object arrives at the first muting sensor. Also, install all F3SJ and muting sensors so
that no person is able to accidentally enter the hazardous area while the muting function is enabled.
0V
1
2
3
4
5
6
8
1
2
3
4
5
6
7
8
7
+24V DC
A1
*2
B1
*2
M1
*1 *2
Emitter
Receiver
M1 : Muting lamp
*1 Connect a muting lamp either to an emitter or a
receiver
*2 When the muting function's operation check is
not required, it does not matter if this is open.
(White) Muting input 1
(Brown) 24V
(Pink) Communication line (-)
(Blue) 0V
Shield
(Red) Muting input 2
(Brown) 24V
(Green) Safety output 1
(Pink) Communication line (-)
(Blue) 0V
Shield
(Red) External device monitor input
(White) Safety output 2
(Yellow) Auxiliary output 1
(Yellow) Reset input
(Green) Test input
(Gey) Communication line (+)
(Gey) Communication line (+)
Open
Open
Open