System Configuration and Functions
Override end conditions
When either of the following conditions is satisfied, the function is released.
•When 60 seconds has elapsed under the override status
•All muting sensors are turned OFF
•When the reset input is turns from OFF to ON and/or the test input turns from ON to OFF
Override state can be released if a sensor transitions to lockout as well.
F3SJ's indicators
•Muting input 1 indicator turns ON when an input is applied to muting input 1.
•Muting input 2 indicator turns ON when an input is applied to muting input 2.
•The muting error indicator turns ON when a muting error occurs.
T1
T2
(300ms)
T2
T2
T1
T1
The override function is disabled when T2 exceeds 60 seconds or if a reversal
occurs in any of the areas to designated by dotted lines.
Reset input
ON
OFF
Muting input 1
ON
OFF
Muting input 2
ON
OFF
Override function
Enabled
Disabled
Test input
ON
OFF
Safety output
ON
OFF
ON
OFF
T1: Muting input time limit
T2: Muting time limit
Muting lamp
(External indicator)
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles