73
F3SJ-A
User’s Manual
Ch
apt
e
r
3
Dimen
s
ions
Wiring/Installation
E
F3SN replacement correspondence table (F3SN mounting holes can be used without modification)
•When replacing F3SN-
P14 with F3SJ-A
P14
For lengths greater than the F3SN-
0234P14:
Add 11 to the F3SN's 4-digit number and apply it as the F3SJ's 4-digit number, and then replace with
the standard brackets included with the product.
[Selection example] F3SN-A0315P14 becomes F3SJ-A0326P14 (replace with standard brackets)
- The protective height is 11mm longer.
- Replace with outward-facing mounting of F39-LJ5 when you want to set the detection surface height to be same as
the F3SN.
However, the F39-LJ5 and intermediate mounting brackets cannot be mounted simultaneously, so set the protective
height to 600mm or less.
•When replacing F3SN-
P25 with F3SJ-A
P20
For lengths greater than the F3SN-
0262P25:
Subtract 17 from the F3SN's 4-digit number and apply it as the F3SJ's 4-digit number, and then
replace with the standard brackets included with the product.
[Selection example] F3SN-A0322P25 becomes F3SJ-A0305P20 (replace with standard brackets)
- The protective height becomes 17mm shorter.
- Replace with outward-facing mounting of F39-LJ5 when you want to set the detection surface height to be same as
the F3SN.
However, the F39-LJ5 and intermediate mounting brackets cannot be mounted simultaneously, so set the protective
height to 600mm or less.
F3SN
Replacement F3SJ
Replacement method
using F39-LJ5
Model name
Protective height
Model name
Protective height
F3SN-
0153P14
153
-
-
-
F3SN-
0180P14
180
F3SJ-A0245P14
245
Inward-facing mounting
F3SN-
0189P14
189
F3SJ-A0245P14
245
Inward-facing mounting
F3SN-
0198P14
198
F3SJ-A0245P14
245
outward-facing
mounting
F3SN-
0207P14
207
F3SJ-A0245P14
245
outward-facing
mounting
F3SN-
0216P14
216
F3SJ-A0245P14
245
Outward-facing mounting
F3SN-
0225P14
225
F3SJ-A0245P14
245
Outward-facing mounting
F3SN
Replacement F3SJ
Replacement method
using F39-LJ5
Model name
Protective height
Model name
Protective height
F3SN-
0187P25
187
-
-
-
F3SN-
0217P25
217
F3SJ-A0260P20
260
Inward-facing mounting
F3SN-
0232P25
232
F3SJ-A0260P20
260
outward-facing
mounting
F3SN-
0247P25
247
F3SJ-A0245P20
245
Outward-facing mounting
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles