42
Chapter
2
Mu
ting Sys
te
m
F3SJ-A
User’s Manual
System Configuration and Functions
This distance must prevent the muting function from being enabled by a person passing through the
muting sensors. Also, install the F3SJ and muting sensors so that a workpiece passes through all
muting sensors before the next workpiece arrives at the first muting sensor.
Wiring Diagrams
Timing chart
Workpiece
Workpiece
Workpiece
Workpiece
Moving direction
Moving direction
+24V DC
A1
A2
B1
B2
1
8
(White) Muting input 1
(Red) Muting input 2
T2
T1
0.1s
Muting sensor B2
OFF
Safety output
ON
OFF
ON
OFF
Blocked
Unblocked
Muting sensor A2
ON
OFF
Muting sensor A1
ON
ON
OFF
Muting sensor B1
ON
OFF
Muting function
Enabled
Disabled
T1: Muting input time limit
T2: Muting time limit
0.1s max.
0.1s max.
0.1s max.
0.1s max.
Muting lamp
(External indicator)
F3SJ Unblocked
/Blocked
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles