User’s Manual
System Configuration and Functions
Resetting Lockout
When the cause of the lockout is removed, the lockout condition can be released by using either of the
following methods.
•Cycle the power back ON
•Set the reset input line open or to 0 to 1.5V for 300ms or longer, and then apply 9 to 24V again (except
for lockout due to a communication error or a wiring error).
External Device Monitoring Function (EDM)
This function detects malfunctions, such as welding, in external relays (or contactors) that control the
hazardous area of a machine.
The wiring and timing chart are the same as those for the basic system. For details, see the following
page.