6-4
Section
AR Area
88
Address
Forced
set/reset
Controlled
by
Details
Function
Bits
AR 18
00
Analog Output 1
Adjustment Enable
ON: Adjustment enabled
OFF: Adjustment disabled
User
Enabled
01
Analog Output 2
Adjustment Enable
OFF: djustment disabled
Enabled in adjustment mode (DM 6631 in
Unit Setting Area set to 5A5A Hex).
02
Adjusted Mode
Adjustment Item
Specifies either the offset value or the gain
value as the item to be adjusted.
OFF: Offset value
ON: Gain value
The value specified here can be adjusted
with the Adjustment Up Bit or Adjustment
Down Bit.
03
(Reserved by system.)
04
Adjustment Up Bit
While this bit is ON, the offset value or the
gain value increases by 1 (resolution) every
0.5 s.
05
Adjustment Down Bit
While this bit is ON, the offset value or the
gain value decreases by 1 (resolution) every
0.5 s.
06
Adjustment Clear
(reset to factory
settings)
ON: Cleared.
OFF: Not cleared.
Enabled in adjustment mode (DM 6631 in
Unit Setting Area set to 5A5A Hex).
07
Adjustment Set
The adjustment value is written when this bit
is turned ON after adjusting the value with
the Adjustment Up Bit and Adjustment
Down Bit.
08
Adjustment
Command Operation
Error
This flag turns ON when an operational
error, such as turning ON both the
Adjustment Up Bit and the Adjustment
Down Bit together, has been made.
Unit
09 to 14
(Reserved by system.)
15
Adjustment Mode
Operation
ON during adjustment mode (DM 6631 in
Unit Setting Area set to 5A5A Hex).
AR 19
00 to 15
Analog Output 1/
Analog Output 2
Setting Offset
Monitor
Enabled in adjustment mode (DM 6631 in
Unit Setting Area set to 5A5A Hex).
It is possible to write gain values and offset
values here directly without using the
Adjustment Up Bit or Adjustment Down Bit.
Offset values:
–10 to 10 V:
FE0C to 01F4 Hex
Unit/User
AR 20
00 to 15
Analog Output 1/
Analog Output 2
Setting Gain Monitor
10 to 10 V:
FE0C to 01F4 Hex
0 to 10 V, 0 to 5 V, 1 to 5 V:
FF38 to 00C8 Hex
Gain values:
–10 to 10 V:
1194 to 157C Hex
0 to 10 V, 0 to 5 V, 1 to 5 V:
0ED8 to 1068 Hex
Содержание CS1 -
Страница 1: ...Cat No W378 E1 1 Customizable Counter Units SYSMAC CS1 CS1W HI001 HCP22 HCA22 OPERATION MANUAL...
Страница 2: ......
Страница 3: ...CS1W HIO01 HCP22 HCA22 Customizable Counter Units Operation Manual Produced January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 10: ......
Страница 20: ......
Страница 40: ......
Страница 60: ......
Страница 146: ......
Страница 166: ......