Required calibration cards: 

1 x pink calibration card, 10 x grey calibration cards,  

10 x white calibration cards

CALIBRATION INSTRUCTIONS 

rapidcount T 575

[EN]

ratiotec GmbH & Co. KG | Tel.: +49 201 361 490 | Fax: +49 201 361 49 26 | Email: [email protected]

Connect the power adapter with the device. 
Turn on the device. Then press the 

“CLEAR“

 

button 

5

 times. A window with „Input Pass-

word“ opens on the display . Please enter a 0 
and confirm it with the 

“START“

 button.

Now the “Maintenance Menu“ opens. Select 
“Sensor Adjust“ and confirm it with the 

“START“

 button. Afterwards please press the 

“REPORT“

 button to get to “Static Adjust“. 

Confirm it again with the 

“START“

 button.

Open the cover of the device so that the feed 
rollers are visible. Place the pink calibration 
card centrally under the feed roller. Then close 
the cover and press the 

“START“

 button. The 

calibration card is automatically ejected after 
the calibration.

Press the 

“REPORT“

 button to get to “Image 

Dynamic Adjust“. Confirm it with the 

“START“

 

button. Place all gray calibration cards on the 
upper feed. Repeat this process until “Press 
START key“ is shown.

pink 

calibration card!

grey 

calibration cards!