5-1
Section
Unit Setup Area
57
5-1-2 Details of Overall Unit Settings
Settings Enabled at Startup
Address
Bits
Function
Contents
DM 6600
00 to 03
Disable writing to user memory (UM protect)
0 Hex: Writing enabled
1 Hex: Writing disabled
Note: Set these bits to 1 (Hex) to
prohibit writing to the following
areas from the Programming
Device: User program, read-only
portion of the DM Area, Unit Setup
Area (except for bits 00 to 03 in
DM 6600), and expansion function
data.
04 to 07
Switch between English and Japanese for Programming
Console messages
0 Hex: English
1 Hex: Japanese
08 to 11
Enable user settings for expansion instructions
0 Hex: Default settings
1 Hex: User settings
12 to 15
Holding EM Area
0 Hex: Clear
1 Hex: Held
DM 6601
00 to 07
General-purpose
I/O between the
Input refresh (for
inputs from the
C
No. of refresh
words
00 (BCD): Not refreshed
01 to 32 (BCD): 1 to 32 words
08 to 15
/O be
ee
e
LR Area and
user-set words in
the CPU Unit
s o
e
CPU Unit to the
Customizable
Counter Unit)
CPU Unit area
00 (BCD): CIO
01 (BCD): WR
02 (BCD): AR
03 (BCD): HR
04 (BCD): DM
05 (BCD): EM
DM 6602
00 to 07
Output refresh
(for outputs from
C
No. of refresh
words
00 (BCD): Not refreshed
01 to 32 (BCD): 1 to 32 words
08 to 15
( o o
s o
the Customizable
Counter Unit to
the CPU Unit)
CPU Unit area
00 (BCD): CIO
01 (BCD): WR
02 (BCD): AR
03 (BCD): HR
04 (BCD): DM
05 (BCD): EM
DM 6603
00 to 15
Input refresh
First word in CPU
Unit area
0000 to 9999 (BCD): 0 to 9999
DM 6604
00 to 15
Output refresh
First word in CPU
Unit area
0000 to 9999 (BCD): 0 to 9999
DM 6605
to
DM 6614
00 to 15
Special I/O Setup Area
---
Содержание CS1 -
Страница 1: ...Cat No W378 E1 1 Customizable Counter Units SYSMAC CS1 CS1W HI001 HCP22 HCA22 OPERATION MANUAL...
Страница 2: ......
Страница 3: ...CS1W HIO01 HCP22 HCA22 Customizable Counter Units Operation Manual Produced January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 10: ......
Страница 20: ......
Страница 40: ......
Страница 60: ......
Страница 146: ......
Страница 166: ......