3-4
Section
Programming Devices
36
•
CX-Programmer Ver. 1.2 or later (register the PC model as a CQM1H-CPU61.)
Note
1. The Customizable Counter Unit cannot be used with CX-Programmer Ver.
1.1 or earlier.
2. The SYSMAC-CPT or SYSMAC Support Software cannot be used.
The functions available when using a Programming Device with the Customiz-
able Counter Unit are the same as when using one with a CPU Unit with the fol-
lowing exceptions.
•
PC Setup functions
•
Reading the error log
•
PC clock
•
Forced set/reset of the PC
•
Data trace
•
Reading the cycle time
•
PC information display
Note Before using the CX-Programmer, refer to the appendix, Precautions in Using
the CX-Programmer.
The following settings are required when using a Programming Device.
Programming Device Connection Switch
You must turn ON the Programming Device connection switch on the front of the
Unit before connecting a Programming Device to the peripheral port. It will not be
possible to connect to the Programming Device if this switch is turned OFF. (Turn
OFF this switch, however, to prevent malfunctions due to operational errors.)
Programming Device connection
switch
Programming Device
Set to ON:
TOOL
ON
OFF
Connection enabled
(The switch must be turned ON to use a
Programming Device.)
Set to OFF:
TOOL
ON
OFF
Connection disabled
(Turn OFF the switch to prevent
operational errors.)
Unit Setup Area
When connecting a Programming Device to the peripheral port, depending on
the type of Programming Device, the serial communications mode, and commu-
nications conditions used, the Unit Setup Area (DM 6650 to DM 6651) settings
may or may not be necessary. This is shown in the following table.
Programming Device
Serial
communications
mode (recognized
by Unit)
Communications
conditions
Unit Setup Area
(DM 6650 to
DM 6651)
Setting in
CX-Programmer
Programming Console
(Programming
Console bus)
---
Settings not required
---
CX-Programmer
Peripheral bus
9,600 bps
Settings not required
Set to the same
i
i
g
Other than above
Set in DM 6650 to
DM 6651 (baud rate
only)
communications
conditions.
3-4-1 Programming Consoles
The following three Programming Console are available:
•
CQM1H-PRO01
•
CQM1-PRO01
•
C200H-PRO27
Functions Supported by
Programming Devices
Settings
Содержание CS1 -
Страница 1: ...Cat No W378 E1 1 Customizable Counter Units SYSMAC CS1 CS1W HI001 HCP22 HCA22 OPERATION MANUAL...
Страница 2: ......
Страница 3: ...CS1W HIO01 HCP22 HCA22 Customizable Counter Units Operation Manual Produced January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 10: ......
Страница 20: ......
Страница 40: ......
Страница 60: ......
Страница 146: ......
Страница 166: ......