107
Connecting External I/O for Slave Units
Section 3-6
■
Connecting Loose Wires to Devices
The following table shows the Cables available when the Slave Unit has a MIL
connector and the other device has loose wires. Use these Cables as needed.
The following table shows the MIL connector pin numbers, loose wire colors,
dot markings, and dot colors.
20 Pins (G79-A
@@@
C)
Three-tier with common terminal
XW2E
Screw-less clamp terminals
XW2F
e-CON connector
XW2N
Type
Series
Slave model
MIL Cable model
Remarks
CRT1-V
@
D16ML
20 pins
G79-A200C (2 m)
G79-A500C (5 m)
Loose wire size: AWG24
Loose wires are cut.
G79-Y100C (1 m)
G79-Y150C (1.5 m)
G79-Y200C (2 m)
G79-Y300C (3 m)
G79-Y500C (5 m)
Forked terminals are attached to the loose
wires.
Forked terminal: 161071-M2
(Nippon Terminal)
CRT1-V
@
D32ML
40 pins
G79-A200C-D1 (2 m)
G79-A500C-D1 (5 m)
Loose wire size: AWG28
Loose wires are cut.
G79-Y100C-D1 (1 m)
G79-Y200C-D1 (2 m)
G79-Y500C-D1 (5 m)
Forked terminals are attached to the loose
wires.
Forked terminal: 161071-M2
(Nippon Terminal)
CRT1-VDA02ML
10 pins
Indicated cable is not available
CRT1-VAD04ML
16 pins
Pin No.
Wire color
Dots
Dot color
Pin No.
Wire color
Dots
Dot color
20
Light brown
Black
10
Light brown
Black
19
Red
9
Red
18
Yellow
Black
8
Yellow
Black
17
Red
7
Red
16
Light green
Black
6
Light green
Black
15
Red
5
Red
14
Gray
Black
4
Gray
Black
13
Red
3
Red
12
White
Black
2
White
Black
11
Red
1
Red
Содержание CRT1 - 10-2009
Страница 1: ...Cat No W457 E1 07 CompoNet Slave Units and Repeater Unit CRT1 Series OPERATION MANUAL...
Страница 2: ......
Страница 3: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2009...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 10: ...x...
Страница 16: ...xvi...
Страница 24: ...xxiv Conformance to EC Directives 6...
Страница 386: ...362 Units with Connectors Section 6 7...
Страница 414: ...390 Temperature Input Units Section 7 5...
Страница 430: ...406 Expansion Unit Specifications Section 8 2...
Страница 486: ...462 Bit Slave Units with Compact Connectors Section 9 5 Dimensions CRT1B MD02JS and CRT1B MD02JS 1 15 21 65 24 48 9 mm...
Страница 494: ...470 Bit Slave Units with Compact Connectors Section 9 5...
Страница 501: ...477 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Страница 502: ...478 Repeater Unit Section 10 2...
Страница 508: ...484 CX Integrator Section 11 1...
Страница 509: ...485 CX Integrator Section 11 1...
Страница 602: ...578 Temperature Input Unit Functions Section 11 6...
Страница 614: ...590 Device Maintenance Section 12 3...
Страница 664: ...640 I O Power Supply Current Appendix E...
Страница 672: ...648 Index...
Страница 674: ...650 Revision History...