Functions Common to All Slave Units
Section 11-2
11-2 Functions Common to All Slave Units
This section describes the functions common to all CompoNet Slave Units
and the procedures for using these functions.
The functions described in
11-2-1 Automatic Baud Rate Detection
and
11-2-2
Hold/Clear Outputs
are supported by Bit Slave Units with Compact Connec-
tors.
11-2-1 Automatic Baud Rate Detection
Description
The CompoNet Slave Units are automatically set to the same baud rate as the
Master Unit. It is not necessary to set the baud rate separately for any Slave
Unit.
The baud rate is set when communications is established with the Master Unit
after the power is turned ON. The baud rate setting is stored in memory until
the power is turned ON again or until the Master Unit baud rate setting is
changed.
11-2-2 Hold/Clear Outputs
Description
Output Units can be set to hold or clear outputs when an error occurs.
Procedure Using CX-
Integrator
1,2,3...
1.
Turn ON the power to the CompoNet Slave Unit.
2.
Double-click the icon of the Slave Unit to set in the Network Configuration
Window to open the Configuration Window. (Alternatively, right-click the
icon and select
Parameters - Edit
from the pop-up menu.)
3.
Click the
OUT
Tab.
4.
Double-click
I/O Comment
for the terminal to be set. The Edit Terminal
Window will be displayed. Select either to clear or hold outputs when a
communications error (
Fault Action
) and idle state (
Idle Action
) occurs, and
then click the
OK
Button.
Содержание CRT1 - 10-2009
Страница 1: ...Cat No W457 E1 07 CompoNet Slave Units and Repeater Unit CRT1 Series OPERATION MANUAL...
Страница 2: ......
Страница 3: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2009...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 10: ...x...
Страница 16: ...xvi...
Страница 24: ...xxiv Conformance to EC Directives 6...
Страница 386: ...362 Units with Connectors Section 6 7...
Страница 414: ...390 Temperature Input Units Section 7 5...
Страница 430: ...406 Expansion Unit Specifications Section 8 2...
Страница 486: ...462 Bit Slave Units with Compact Connectors Section 9 5 Dimensions CRT1B MD02JS and CRT1B MD02JS 1 15 21 65 24 48 9 mm...
Страница 494: ...470 Bit Slave Units with Compact Connectors Section 9 5...
Страница 501: ...477 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Страница 502: ...478 Repeater Unit Section 10 2...
Страница 508: ...484 CX Integrator Section 11 1...
Страница 509: ...485 CX Integrator Section 11 1...
Страница 602: ...578 Temperature Input Unit Functions Section 11 6...
Страница 614: ...590 Device Maintenance Section 12 3...
Страница 664: ...640 I O Power Supply Current Appendix E...
Страница 672: ...648 Index...
Страница 674: ...650 Revision History...