Cobra 350 User's Guide
05624-000 Rev. K
6.3 Front Panel
!
CAUTION:
PROPERTY DAMAGE RISK
When the Brake Release button is pressed, Joint 3 may drop to the bottom of its
travel. To prevent possible damage to the equipment, make sure that Joint 3 is
supported while releasing the brake and verify that the end-effector or other
installed tooling is clear of all obstructions.
6.3 Front Panel
NOTE:
The factory-supplied Front Panel E-Stop is designed in accordance with
the requirements of IEC 60204-1 and ISO 13849.
IMPORTANT:
Any user-supplied front panel E-Stop must be designed in accord-
ance with the requirements of IEC 60204-1 and ISO 13849. The push button of
the E-Stop must comply with ISO 13850 (Clause 5.5.2).
1
2
5
4
3
Figure 6-2. Front Panel
1.
XFP connector
Connects to the XFP connector on the eAIB XSYSTEM cable (or the optional SmartCon-
troller EX, if one is being used).
2.
System 5 V Power-On LED
Indicates whether or not power is connected to the robot.
3.
Manual/Automatic Mode Switch
Switches between Manual (
) and Automatic (
) mode. In Automatic mode,
executing programs control the robot, and the robot can run at full speed. In Manual
mode, the system limits robot speed and torque so that an operator can safely work in
the cell. Manual mode initiates software restrictions on robot speed, commanding no
more than 250 mm/sec.
There is no high speed mode in manual mode.