Chapter 5: System Cable Installation
Step
Connection Description
Item
9
Connect Ethernet cable from switch to eMB-40R.
Refer to Connecting the PC to the SmartController EX on page 65 for more
information.
M, O, R
10
Connect Ethernet cable from switch to SmartVision MX, if used.
Refer to Connecting the PC to the SmartController EX on page 65 for more
information.
N, O
11
Connect optional camera and cable to SmartVision MX, if used.
P
12
Connect Ethernet cable from PC to switch if used.
Refer to Connecting the PC to the SmartController EX on page 65 for more
information.
T, U
NOTE:
A front panel ships with each Cobra 350 robot system, but you can
choose not to use it if you replace its functionality with equivalent circuits. That
is beyond the scope of this guide.
Other Cables
NOTE:
The following cables are not covered in the steps in the preceding table.
Refer to Optional Cables on page 60 for more information.
Part Description
Notes
XIO Breakout Cable
, 12 inputs/
8 outputs, 5 m
Available as option
eAIB XBELT IO Adapter Cable
Available as option
05624-000 Rev. K
Cobra 350 User's Guide
55