![background image](http://html1.mh-extra.com/html/omron/3g8f7-crm21/3g8f7-crm21_user-manual_743553072.webp)
52
PC Watchdog Timer
Section 4-7
4-7
PC Watchdog Timer
The CompoNet Master Board has the PC Watchdog Timer (PC WDT)
function. This is used to stop the communications automatically whenever the
user application, by which the Board is controlled, stops. While the PC WDT
function is enabled, the communications automatically stops unless the user
application updates the timer value within a specified timeframe. The user
application must be set so that the timer value for the PC WDT is refreshed
periodically, and the correct operation is notified to the Board.
Here is the procedure by which to use the API function and enable the PC
WDT on the Board.
Loop Start
(Open Board)
CPNT_Open
Final processing
Loop End
(Close Board)
CPNT_Close
Initial processing
I/O process and so on
(Start Communications cycles)
CPNT_StartCycle
(Enable PC WDT)
CPNT_EnablePCWDTTimer
(Refresh PC WDT value)
CPNT_RefreshPCWDTTimer
(Disable PC WDT)
CPNT_EnablePCWDTTimer
(Stop Communications cycles)
CPNT_StopCycle
Содержание 3G8F7-CRM21
Страница 4: ...iv...
Страница 10: ...x TABLE OF CONTENTS...
Страница 30: ...10 Specifications Section 1 7 1 7 3 Dimensions 3G8F7 CRM21 PCI unit mm 3G8F8 CRM21 CompactPCI unit mm...
Страница 46: ...26 Connecting the Communications Power Supply Cables Section 2 4...
Страница 74: ...54 Board Hardware Error Notification Section 4 8...
Страница 173: ...153 APPENDIX D Sample Program D 1 Sample Program 154...
Страница 230: ...210 Wiring for Power Supply Section E 5...
Страница 234: ...214 Index...
Страница 236: ...216 Revision History...
Страница 237: ......