94
Explicit Messaging API
Section A-6
Remarks
To execute this function, the communications cycles must be running.
CPNT_EXPLICIT_REQ structure
A-6-2
CPNT_PeekExplicit (Check Response Received)
Purpose
Check Explicit message responses.
Call Format
BOOL CPNT_PeekExplicit (HANDLE Handle) ;
Argument
Returned value
It returns TRUE when there is an explicit message response.
It returns FALSE when an error occurs or when there is no response. The
error details can be obtained with the function GetLastError.
Remarks
The function CPNT_SendExplicit must be executed prior to this function.
A-6-3
CPNT_RegReceiveExplicitNotifyMessage (Register Notice of
Explicit Response Message Received)
Purpose
Register the Windows message which notifies that an Explicit response
message is received.
Type
Parameter
Description
BYTE
Sid
This is used to identify to which explicit
message a response is addressed. The
same value is added to the response of a
sent explicit message.
Set a certain value for the user application.
Settable range: 0 to 255
BYTE
Rsv
Reserved area. Set 0.
WORD
DstMacId
MAC address (or the address over
CompoNet protocol) of the destination Slave
Unit,
[For Word IN Slave Unit]
MAC address=Node address
[For Word OUT Slave Unit]
MAC address=64+Node address
[For Bit IN Slave Unit]
MAC address=128+Node address
[For Bit OUT Slave Unit]
MAC address=256+Node address
[For Repeater]
MAC address=384+Node address
[For Master]
MAC address=448
WORD
ServiceCode
Set the service code of the explicit message.
WORD
ClassId
Set the Class ID of the explicit message.
WORD
InstanceId
Set the Instance ID of the explicit message.
WORD
ServiceDataSize
Set the Service data size (in bytes) of the
explicit message.
Specified range: 0x0000 to 0x0214 (0 to 532)
BYTE
ServiceData[532]
Set the Service data of the explicit message.
Type
Parameter
Direction
Description
HANDLE
Handle
IN
Device handle obtained with the
function CPNT_Open
Содержание 3G8F7-CRM21
Страница 4: ...iv...
Страница 10: ...x TABLE OF CONTENTS...
Страница 30: ...10 Specifications Section 1 7 1 7 3 Dimensions 3G8F7 CRM21 PCI unit mm 3G8F8 CRM21 CompactPCI unit mm...
Страница 46: ...26 Connecting the Communications Power Supply Cables Section 2 4...
Страница 74: ...54 Board Hardware Error Notification Section 4 8...
Страница 173: ...153 APPENDIX D Sample Program D 1 Sample Program 154...
Страница 230: ...210 Wiring for Power Supply Section E 5...
Страница 234: ...214 Index...
Страница 236: ...216 Revision History...