187
Preparing and Mounting Flat Connectors on the Cables
Section E-4
Note
Once it is attached, the housing cannot be removed from the cover. If you
attempt to remove it forcibly, you may damage the connector.
5.
Pressure-Welding the Connector
Use a DWT-A01 Special Tool (Pliers) to pressure-weld and connect the cable.
5-1 Align the center (see arrow) of the connector cover with the center of
the pressure-welding block on the DWT-A01 Pliers.
5-2 Squeeze the Pliers firmly until the lock on Connector clicks into place.
Precautions for Correct Use
•
Do not pressure-weld the connector cover at the edge.
•
Do not use the back of pressure-welding block to pressure-weld the
connector cover.
•
Set the Connector in the correct orientation.
5-3 Confirm that it is properly pressure-welded as shown below:
Connector cover
Special Tool (Pliers)
OK
NG
NG
No space here.
It must be locked on both right and left.