83
Communications Control API
Section A-3
I/O size information format
A-3-3
CPNT_StopCycle (Stop Communications Cycles)
Purpose
Stop the communications cycles.
Call Format
BOOL CPNT_StopCycle(HANDLE Handle);
WORD
VendorCode[3
84]
These items must be set when the relevant flags for
RegSet are selected to check.
Set the values of Slave Unit Identity object
information.
WORD
DeviceType[38
4]
WORD
ProductCode[
384]
BYTE
MajorRevision[
384]
Bit
Flag
Description
0 to 4
Number of IN
channels (points)
Set the number of IN points of Slave Units.
Set the Bits 0 to 5 to 0 (OFF), when the number of IN
points is zero.
=00000: 2 points, =00001: 4 points,
=00010: 8 points, =00011: 16 points,
=00100: 32 points, =00101: 48 points,
=00110: 64 points, =00111: 80 points,
=01000: 96 points, =01001: 112 points,
=01010: 128 points, =01011: 144 points,
=01100: 160 points, =01101: 176 points,
=01110: 192 points, =01111: 208 points,
=10000: 224 points, =10001: 240 points,
=10010: 256 points, others: prohibited
5
IN setting enabling
flag
0: Disabling IN number setting
1: Enabling IN number setting
6 to 7
Reserved area
Set 0 (OFF).
8 to 12 Number of OUT
channels
Set the number of OUT points for Slave Units.
Set the Bits 8 to 13 to 0 (OFF), when the number of
OUT points is zero.
=00000: 2 points, =00001: 4 points,
=00010: 8 points, =00011: 16 points,
=00100: 32 points, =00101: 48 points,
=00110: 64 points, =00111: 80 points,
=01000: 96 points, =01001: 112 points,
=01010: 128 points, =01011: 144 points,
=01100: 160 points, =01101: 176 points,
=01110: 192 points, =01111: 208 points,
=10000: 224 points, =10001: 240 points,
=10010: 256 points, others: prohibited
13
Out setting enabling
flag
0: Disabling OUT number setting
1: Enabling OUT number setting
14
Reserved area
Don't care
15
Slave-Unit enabling
flag
Enable the relevant flag, when a Slave Unit is
registered.
0: All setting is invalid. (No Slave Unit is registered.)
1: All setting is valid. (The Slave is registered.)
Type
Parameter
Description
Содержание 3G8F7-CRM21
Страница 4: ...iv...
Страница 10: ...x TABLE OF CONTENTS...
Страница 30: ...10 Specifications Section 1 7 1 7 3 Dimensions 3G8F7 CRM21 PCI unit mm 3G8F8 CRM21 CompactPCI unit mm...
Страница 46: ...26 Connecting the Communications Power Supply Cables Section 2 4...