63
Information “error messages”
Display
Action
Description
error messages
22.10.12 10:31
not ignited
18.10.12 22:45
door open
The last 5 error messages are displayed.
Information “operating data”
Display
Action
Description
operating data
flame
exhaust
5
576°C
1998rpm
heat power
pressure 18Pa
boiler
buffer 1
buffer 2
65°C
43°C
70°C
pump
on
The following actual data is displayed:
- flame temperature
- speed of the induced draught fan (exhaust)
- heat power level
- underpressure
- Water temperature in the stove (boiler)
- Water temperature in the upper buffer (buffer 1)
- Water temperature in the lower buffer (buffer 2)
- Pump on or off
Child safeguard
Display
Action
Description
To avoid an inadvertent adjustment or unauthorised
use of the appliance, you can activate the child safe-
guard.
Press (ESC) and then within 1.5 seconds press the
“Party-key”.
temp.: 18 / 22°C
heating
Tu,08:55
automatic
Deactivation:
Press (ESC) and then within 1.5 seconds press the
“Party-key”.