40
Introduction
This pellet stove is a top-quality product of modern
heating technology.
Great operating convenience, modern control technol-
ogy and efficient combustion technology permit use as
a high-quality room heater, without having to dispense
with the pleasant atmosphere of a fireplace.
Proper set-up, as well as correct handling and care
are indispensable for trouble-free operation and a long
service life. Please read all the information contained
in this manual carefully. The manual contains impor-
tant information on safety, installation, use and mainte-
nance of the appliance.
The manufacturer assumes no liability if the instruc-
tions below are not complied with. The appliance must
not be used improperly, i.e. for purposes other than the
intended use.
Keep this manual in a safe place so that at the begin-
ning of the heating period you can always refresh your
knowledge of proper operation.
Transport damage must be reported to your supplier
immediately (within 2 days).
General warnings
●
The appliance is not suitable for unsupervised use by
children or by persons with learning disabilities, lim-
ited sensory capacity or physical disabilities. Ensure
that it is not operated by persons who, due to lack of
experience and/or knowledge, might not be aware of
the risks associated with it, unless they are super-
vised and instructed by a person who has read the
operating manual. Ensure that the appliance cannot
be switched on by children while unsupervised.
●
In automatic operation, and with stored frost protec-
tion temperature, or operation via GSM module the
appliance can also go into operation when you are
absent. In this case you must ensure that flamma
-
ble objects, pets or persons requiring help are not in
the direct radiation area at any time, or, in the case
of objects, are not placed on the stove, at any time.
Persons who do not operate the stove but who have
access to it must be provided with this information.
●
Many of the stove’s surfaces become very hot. This
also includes handles, operating lever, locking mech-
anisms, etc. Consequently these parts must only be
touched with protective clothing. Also when operat-
ing the touch control panel you must ensure that you
are not in the direct radiation area of the appliance or
that your clothing touches hot surfaces.
Technical data
●
Rated heat output .......................................... 8.0 kW
●
Room heat output .......................................... 0,7 kW
●
Thermal output, water .................................. 7,3 kW
●
Water content ..................................................... 15 l
●
Dimensions (W x D x H) ......... 483 x 481 x 1116 mm
●
Height to middle
connection duct - waste air pipe ............... 129,5 mm
●
Connection duct - waste air pipe ............... Ø 80 mm
●
Height to middle combustion air duct ....... 129,5 mm
●
Combustion air duct .................................. Ø 80 mm
●
Weight ............................................................112 kg
●
Capacity - pellet tank .......................... approx. 20 kg
●
Pellet consumption
max. heat power ............................. approx. 1.8 kg/h
●
Operation mode ......................... Continuous burning
●
Power supply ......................... 230V / 50/60Hz; 1.6 A
Regulations to be observed
●
Local and statutory building regulations.
●
The stove must be set up and connected to the
chimney by a specialist. The country-specific regu
-
lations must be complied with for safe installation of
the connecting piece.
●
Installation and connection of electrical appliances
must only be executed by a qualified electrician.
●
A regular inspection of the stove must be executed
by a specialist.
●
The stove has national technical approval from the
Deutschen Instituts für Bautechnik (DIBt) (German
Institute for Civil Engineering) for room-air independ-
ent operation.
Chimney dimensioning
The chimney is dimensioned in accordance with
DIN EN 13384 - 2 or in accordance with country-spe-
cific regulations.
Required data
●
Rated heat output .......................................... 8.0 kW
●
Partial heat output ......................................... 2.4 kW
● Waste air mass flow rate
............................... 7.1 g/s
●
Waste air temperature at connection duct ... 129.4°C
●
Minimum delivery pressure
at rated heat output ..................................... 11.2 Pa
●
Minimum delivery pressure
at partial heat output .......................................9.1 Pa
●
Max. operating pressure of water ................. 2,5 bar
At excessive delivery pressures >20 Pa a delivery
pressure limitation element must be implemented (e.g.
secondary air regulator in the chimney).
For the chimney calculation the required delivery pres-
sure at the waste air duct must be set to 0 Pa.
Multiple flues in the chimney are possible with special
permission. Speak with your district master chimney
sweep.