59
Settings “max. power”
only for “automatic” mode
Display
Action
Description
settings
night set
max. power
frost pro
5°C
12°C
5
or
The maximum power level between 1-5 can be set:
- Power level 1 corresponds to 2.6 kW
- Power level 5 corresponds to 8.0 kW
Factory setting: 5
Select the power level with (ENTER) (the value
flashes), set the value with ↓ or ↑ and confirm with
(ENTER).
Settings “standby”
only for “automatic” mode
Display
Action
Description
settings
standby
max. power
night set
12°C
3
on
or
With switched off standby mode the appliance heats,
when reaching the preset room temperature, contin-
ues at the lowest power level. This avoids ignition
processes.
In standby mode the appliance switches off when
reaching the set room temperature plus the set
switch off hysteresis (1°C to 3°C) (see menu „set-
tings temperatur off“).
The temperature at which the appliance will again be
switched on is described in the menu “settings tem-
perature drop”.
If standby operation is not desired, the display must
be changed to “off”.
Select “on” with (ENTER) (“on” flashes), and with ↓
or ↑ change to “off”.
Confirm “off” with (ENTER).
Settings “temperature drop”
only for “automatic” mode
Display
Action
Description
settings
standby
max. power
temp drop
3
on
2
°C
or
Temperature drop describes the switching difference
between the set room temperature and switching
back on of the appliance in standby operation.
Adjustable temperature range: 1°C - 6°C
Factory setting: 2°C
Select the temperature with (ENTER) (the value
flashes), set the value with ↓ or ↑ and confirm with
(ENTER).