60
Settings “temperature off”
only for “automatic” mode
Display
Action
Description
settings
standby
temp drop
on
2 °C
temp. off
1
°C
or
In the “temperature off” menu the switch off hyster-
esis will be set at which the appliance in standby
mode switched off.
Adjustable temperature range: 1°C - 3°C
Factory setting: 1°C
Select the temperature with (ENTER) (the value
flashes), set the value with ↓ or ↑ and confirm with
(ENTER).
Example:
Set room temperature:.. 20°C
Set temperature drop:..... 2°C
Set temperature off: ........ 1°C
Appliance goes into standby at: 20°C + 1°C = 21°C
Appliance reignites at: ...............20°C – 2°C = 18°C
Settings “delay”
Display
Action
Description
settings
temp. off
1°C
delay
---
temp drop
2°C
or
If an external room thermostat is connected the de-
lay can be set from 1 to 9 minutes or “---”. Through
this measure the appliance continues to run, after
reaching the preset room temperature by the time
defined in the delay, in order to prevent or ignore fast
temperature changes or fluctuations of the external
room thermostat (e.g. due to brief opening of a win-
dow).
Factory setting: ---
Select the minutes with (ENTER) (the value flashes),
set the value with ↓ or ↑ and confirm with (ENTER).