3-57
3.12.5 SRAM Check
This mode is used to test the SRAM memory where user programmed parameters such as date,
time, TTI, etc are stored.
Note: When this test is executed, an All RAM Clear will be performed by the unit.
The All RAM Clear erases all user settings and resets all memory switches, machine parameters and
unique switches to factory defaults.
1. Press PROGRAM, *, B. Then press One-touch E.
SRAM Check
Enter/Stop
2. Press
ENTER
.
Note: To finish the operation without performing SRAM check, press
STOP
.
The values FF, AA, 55, and 00 are written to, then read from, memory. The results are shown in
the display. If the read/write test is successful the display will show “OK” after each value.
SRAM Check
FF:OK
SRAM Check
AA:OK
SRAM Check
55:OK
SRAM Check
00:OK
If some portion of the read/write test fails the display will show “NG” after the failed value.
SRAM Check
FF:NG 413000:A5
3. Upon completion, the unit will return to the standby mode.
Содержание OKIOFFICE 120
Страница 7: ...vi ...
Страница 17: ...1 10 1 7 Dimensions Dimension in mm ...
Страница 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Страница 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Страница 25: ...2 2 ...
Страница 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...
Страница 190: ...5 60 Note If you re attach the feed roller B put the right and left nibs into the fixing hole as shown ...
Страница 195: ...5 65 10 Move the cassette PCB by sliding it 11 Disconnect the all connectors on the cassette PCB ...