3-25
Memory Switch G:1 - Remote reception
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Off-hook / on-hook detect
time (remote reception)
Sets the time interval between the off-hook/on-hook
condition for remote reception.
Switch 7 6 5 4 Time
0 0 0 0 0 ms
0 0 0 1 10 ms
6
0
0 0 1 0 20 ms
0 0 1 1 30 ms Default
0 1 0 0 40 ms
0 1 0 1 50 ms
0 1 1 0 60 ms
5
1
0 1 1 1 70 ms
1 0 0 0 80 ms
1 0 0 1 90 ms
1 0 1 0 100 ms
1 0 1 1 110 ms
4
1
1 1 0 0 120 ms
1 1 0 1 130 ms
1 1 1 0 140 ms
1 1 1 1 150 ms
3
0
Off-hook / on-hook detect
time
Sets the time interval between the on-hook and off-
hook(or off-hook/on-hook) condition.
Switch 3 2 1 0 Time
0 0 0 0 0 ms
0 0 0 1 100 ms
2
1
0 0 1 0 200 ms
0 0 1 1 300 ms
0 1 0 0 400 ms Default
0 1 0 1 500 ms
0 1 1 0 600 ms
1
0
0 1 1 1 700 ms
1 0 0 0 800 ms
1 0 0 1 900 ms
1 0 1 0 1000 ms
1 0 1 1 1100 ms
0
0
1 1 0 0 1200 ms
1 1 0 1 1300 ms
1 1 1 0 1400 ms
1 1 1 1 1500 ms