
4-22
RX Motor Error
Symptom: RX motor malfunction
Suggested corrective action:
1. Verify the RX motor rotates when the power is on.
2. Check the connection between RX motor and the main control PCB (P56). (See page 2-2.)
3. Replace the RX motor if it doesn’t rotate.
4. If the problem is not correct, replace the main control board.
Drum Fuse Error
Symptom: The fuse in the new drum cartridge does not disconnect when set the new drum cartridge.
Suggested corrective action:
1. Verify the drum cartridge is set correctly.
2. Check a point of contact between drum cartridge and machine’s electrode.
3. Replace the drum cartridge.
4. Replace the main control PCB.
H-vlt Fuse Disconnect
Symptom: The fuse in the high voltage power supply is disconnect.
Suggested corrective action:
1. Replace the high voltage power supply and the drum cartridge.
Содержание OKIOFFICE 120
Страница 7: ...vi ...
Страница 17: ...1 10 1 7 Dimensions Dimension in mm ...
Страница 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Страница 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Страница 25: ...2 2 ...
Страница 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...
Страница 190: ...5 60 Note If you re attach the feed roller B put the right and left nibs into the fixing hole as shown ...
Страница 195: ...5 65 10 Move the cassette PCB by sliding it 11 Disconnect the all connectors on the cassette PCB ...